Test Bay with minimum dimensions. Width 3600mm with 600mm between any equipment. This will include the Power Pack on the lift.
Headroom 2400mm and 3800mm above the surface of a Lift.
The headroom must extend a further 500mm further than the outer edges of the Lift Platforms.
The headroom must extend a further 500mm further than the front edges of the Lift Platforms and 1.0 metre from the rear edge of the Lift Platforms.
A clearly identified
viewing area to be allocated where the test can be
clearly and comfortably observed.
Area to be level
and true.
Headlamp test standing
area to be 2100mm wide and 3600mm long and level to
within +/- 6mm in any 3000mm. Where tester is in front
of lift, lift platforms must be level to above specifications.
Tester rails to be certified parallel to +/- 2mm of
standing area plane and many be recessed in to floor.
A clear durable headlamp datum line to be marked.
A minimum clearance
of 600mm between any part of the lift and adjacent
wall must be provided.
1000mm high rimovable
barrier rails may be required where distraction or
disruption to the test is likely by non MOT activities.
Vehicles must be
substantially level while being tested (gradient not
more tha 5%).